MS132-6.3
- Cantidad mínima de pedido:
- 1 piece
- Código arancelario:
- 85362010
Descargas Populares
- Ficha técnica, información técnica:
- 2CDC131021D0202
- Instrucciones y manuales:
- 2CDC131022M6802
- Instructions and Manuals (Part 2):
- 2CDC131060M0202
- Time-Current Characteristic Curve:
- 1SAM300505F0009
- I²t Characteristic:
- 1SAM300507F0001
1SAM300507F0003
- Cut-off Current Characteristic:
- 1SAM300508F0001
1SAM300508F0003
- Dimension Diagram:
- 1SAM300402F0001
Dimensiones
- Ancho del product:
- 45 mm
- Alto del producto:
- 90 mm
- Largo del product:
- 86.75 mm
- Peso del product:
- 0.265 kg
Technical
- Rated Service Short-Circuit Breaking Capacity (Ics):
- (230 V AC) 100 kA
(250 V DC) 3 Poles in Series 10 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
- Rated Ultimate Short-Circuit Breaking Capacity (Icu):
- (230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
- Rated Instantaneous Short-Circuit Current Setting (Ii):
- 78.8 A
- Setting Range:
- 4.0 … 6.3 A
- Rated Operational Power AC-3 (Pe):
- (400 V) Three Phase 2.2 kW
- Rated Operational Power AC-3e (Pe):
- (400 V) Three Phase 2.2 kW
- Rated Operational Voltage:
- Main Circuit 690 V AC
Main Circuit 250 V DC
- Rated Operational Current (Ie):
- 6.3 A
- Rated Operational Current AC-3 (Ie):
- 6.3 A
- Rated Operational Current AC-3e (Ie):
- 6.3 A
- Rated Operational Current DC-5 (Ie):
- 6.3 A
- Rated Frequency (f):
- Main Circuit 50 Hz
Main Circuit 60 Hz
- Rated Impulse Withstand Voltage (Uimp):
- Main Circuit 6 kV
- Rated Insulation Voltage (Ui):
- 690 V
- Power Loss:
- at Rated Operating Conditions per Pole 0.7 W
- Number of Poles:
- 3
- Conventional Free-air Thermal Current (Ith):
- Main Circuit 6.3 A
- Grado de protección:
- Housing IP20
Main Circuit Terminals IP10
- Pollution Degree:
- 3
- Electrical Durability:
- 50000 cycle
- Mechanical Durability:
- 100000 cycle
- Terminal Type:
- Screw Terminals
- Connecting Capacity Main Circuit:
- Flexible with Ferrule 1/2x 0.75 … 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 … 2.5 mm²
Flexible 1/2x 0.75 … 2.5 mm²
Rigid 1/2x 1 … 4 mm²
- Tightening Torque:
- Main Circuit 0.8 … 1.2 N·m
- Wire Stripping Length:
- Main Circuit 9 mm
- Recommended Screw Driver:
- Pozidriv 2
- Mounting Position:
- Position 1 to 6
- Mounting on DIN Rail:
- TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
- Minimum Mounting Distance:
- Electrical Conductive Board, Horizontal – Up to 400 V 0 mm
Electrical Conductive Board, Horizontal – Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
- Actuator Type:
- Rotary Handle
- Contact Position Indication:
- ON / OFF / TRIP
- Standards:
- IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
- Remarks:
- UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx
Technical UL/CSA
- Short-Circuit Current Rating (SCCR):
- Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
- Maximum Operating Voltage UL/CSA:
- Main Circuit 600 V AC
- Ampere Rating UL/CSA:
- 6.3 A
- Horsepower Rating UL/CSA:
- (200 V AC) Three Phase 1 Hp
(208 V AC) Three Phase 1 Hp
(220 … 240 V AC) Three Phase 1.5 Hp
(440 … 480 V AC) Three Phase 3 Hp
(550 … 600 V AC) Three Phase 5 Hp
- Full Load Amps Motor Use:
- (200 V AC) Three Phase 6.3 A
(208 V AC) Three Phase 6.3 A
(220 … 240 V AC) Three Phase 6.3 A
(440 … 480 V AC) Three Phase 4.8 A
(550 … 600 V AC) Three Phase 6.1 A
- Locked Rotor Amps:
- (200 V AC) Three Phase 37.8 A
(208 V AC) Three Phase 37.8 A
(220 … 240 V AC) Three Phase 37.8 A
(440 … 480 V AC) Three Phase 32 A
(550 … 600 V AC) Three Phase 36.8 A
- General Use Rating UL/CSA:
- (600 V AC) 6.3 A
- Connecting Capacity Main Circuit UL/CSA:
- Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
- Tightening Torque UL/CSA:
- Main Circuit 10 … 12 in·lb
Ambiente
- Temperatura ambiente:
- Around the Enclosure 0 … +40 °C
Funcionamiento -25 … +70 °C
Operation Compensated -25 … +60 °C
Almacenamiento -50 … +80 °C
- Ambient Air Temperature Compensation:
- Yes
- Maximum Operating Altitude Permissible:
- 2000 m
- Resistance to Shock acc. to IEC 60068-2-27:
- 11 ms Pulse 25g
- Resistance to Vibrations acc. to IEC 60068-2-6:
- 5g / 3 … 150 Hz
- RoHS Status:
- Following EU Directive 2011/65/EU
Certificados y Declaraciones (Número de Documento)
- ABS Certificate:
- 1SAA963001-0101
- ATEX Certificate:
- 1SAA963000-3902
- BV Certificate:
- 1SAA963001-0202
- CB Certificate:
- 1SAA963002-2002
- CQC Certificate:
- CQC2010010307387700
CQC2019010307243864
- cUL Certificate:
- cUL_E137861
cUL_E345003
- cULus Certificate:
- cUL_E137861
- Cut-off Current Characteristic:
- 1SAM300508F0001
1SAM300508F0003
- Declaration of Conformity – CCC:
- 2020980307003526
2020980307003041
- Declaración de conformidad – CE:
- 1SAD938516-0125
- DNV GL Certificate:
- 1SAA963001-0304
- EAC Certificate:
- 1SAA963000-2701
- Environmental Information:
- 1SAC200049H0009
- I²t Characteristic:
- 1SAM300507F0001
1SAM300507F0003
- IECEx Certificate:
- 1SAA963000-4001
- Instrucciones y manuales:
- 2CDC131022M6802
- Instructions and Manuals (Part 2):
- 2CDC131060M0202
- KC Certificate:
- 1SAA963002-1502
- LR Certificate:
- 1SAA963001-0502
- RINA Certificate:
- 1SAA963002-0802
- RMRS Certificate:
- 1SAA918000-0704
- RoHS Information:
- 1SAD938511-0125
- Time-Current Characteristic Curve:
- 1SAM300505F0009
- UL Certificate:
- UL_E137861
UL_E345003
Información de Embalaje
- Embalaje Nivel 1 Unidades:
- box 1 piece
- Embalaje Nivel 1 Ancho:
- 92 mm
- Embalaje Nivel 1 Largo:
- 95 mm
- Embalaje Nivel 1 Alto:
- 50 mm
- Embalaje Nivel 1 Peso:
- 0.28 kg
- Embalaje Nivel 1 EAN:
- 4013614400094
- Package Level 2 Units:
- carton 40 piece
- Package Level 2 Width:
- 280 mm
- Package Level 2 Depth / Length:
- 395 mm
- Package Level 2 Height:
- 210 mm
- Package Level 2 Gross Weight:
- 11.586 kg
- Package Level 2 EAN:
- 4013614408991
Clasificaciones
- Object Classification Code:
- F
- ETIM 4:
- EC000074 – Motor protective circuit-breaker
- ETIM 5:
- EC000074 – Motor protective circuit-breaker
- ETIM 6:
- EC000074 – Motor protection circuit-breaker
- ETIM 7:
- EC000074 – Motor protection circuit-breaker
- eClass:
- V11.0 : 27370401
- UNSPSC:
- 39121521
- IDEA Granular Category Code (IGCC):
- 4845 >> 3 Pole Motor Circuit Protector Circuit Breakers
- E-Number (Finland):
- 3705993
- E-Number (Sweden):
- 3112125