Descripción
Table of Contents
T6N 800 PR221DS-I In=800 3p F F
- EAN:
- 8015644627317
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85362090
Dimensions
- Product Net Width:
- 210 mm
- Product Net Height:
- 268 mm
- Product Net Depth / Length:
- 103.5 mm
- Product Net Weight:
- 9.5 kg
Container Information
- Package Level 1 Units:
- 1 piece
- Package Level 1 Width:
- 305 mm
- Package Level 1 Height:
- 285 mm
- Package Level 1 Depth / Length:
- 370 mm
- Package Level 1 Gross Weight:
- 11 kg
- Package Level 1 EAN:
- 8015644627317
Environmental
- RoHS Status:
- Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Additional Information
- Electrical Durability:
- 5000 cycle
60 cycles per hour
- Mechanical Durability:
- 20000 cycle
120 cycles per hour
- Number of Poles:
- 3
- Power Loss:
- at Rated Operating Conditions per Pole 32 W
- Product Main Type:
- SACE Tmax T
- Product Name:
- Moulded Case Circuit Breaker
- Product Type:
- CB
- Rated Current (In):
- Main Circuit 800 A
- Rated Impulse Withstand Voltage (Uimp):
- 8 kV
- Rated Insulation Voltage (Ui):
- 1000 V
- Rated Operational Voltage:
- 690 V AC
- Rated Service Short-Circuit Breaking Capacity (Ics):
- (220 V AC) 70 kA
(230 V AC) 70 kA
(380 V AC) 36 kA
(400 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 30 kA
(500 V AC) 25 kA
(690 V AC) 15 kA
- Rated Short-time Withstand Current (Icw):
- for 1 s 10 kA
- Rated Ultimate Short-Circuit Breaking Capacity (Icu):
- (220 V AC) 70 kA
(230 V AC) 70 kA
(380 V AC) 36 kA
(400 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 30 kA
(500 V AC) 25 kA
(690 V AC) 20 kA
- Rated Uninterrupted Current (Iu):
- 800 A
- Release:
- PR221DS-I
- Release Type:
- EL
- Short-Circuit Performance Level:
- N
- Standards:
- IEC
- Sub-type:
- T6
- Suitable For:
- T6
- Suitable for Product Class:
- Moulded Case Circuit Breakers
- Terminal Connection Type:
- Fixed Circuit-Breakers
Front
- Test Voltage Max (Utest):
- 3500 V
- Version:
- F
Certificates and Declarations (Document Number)
- Data Sheet, Technical Information:
- 1SDC210015D0201
- Declaration of Conformity – CE:
- 1SDL000165R0006
- Environmental Information:
- 1SDL000194R0003
- GL Certificate:
- 1SDL000163R0057
- Instructions and Manuals:
- 1SDH000511R0001
- REACH Declaration:
- LB-DT 18-21D
- RoHS Information:
- LB-DT 17-21D
Classifications
- ETIM 4:
- EC000228 – Power circuit-breaker for trafo/generator/installation prot.
- ETIM 5:
- EC000228 – Power circuit-breaker for trafo/generator/installation prot.
- ETIM 6:
- EC000228 – Power circuit-breaker for trafo/generator/installation prot.
- ETIM 7:
- EC000228 – Power circuit-breaker for trafo/generator/installation protection
- Object Classification Code:
- Q
- UNSPSC:
- 39121100
- WEEE Category:
- 5. Small Equipment (No External Dimension More Than 50 cm)